1. The storage environment of the vulcanizer should be kept dry and well ventilated to avoid moisture in the electrical circuits due to humidity;
2. Do not use the vulcanizer outdoors on rainy days to prevent water from entering the electric control box and the heating plate;
3. If the working environment is humid and watery, when disassembling and moving the vulcanizer, the ground should be raised with objects to prevent the vulcanizer from direct contact with water;
4. If water enters the heating plate due to improper operation during use, the manufacturer should be contacted for repair first. If emergency repairs are required, the upper cover of the heating plate can be opened, the water can be poured out first, and then the electric control box can be set to manual operation, heated to 100℃, kept at a constant temperature for half an hour, the circuit should be dried, and the belt can be glued in manual mode. At the same time, the manufacturer should be contacted in time to replace the entire line;
5. If the vulcanizer is not needed for a long time, the heating plate should be heated every half a month (the temperature is set at 100℃) and the temperature should be maintained for about half an hour;
6. After each use, the water in the water pressure plate should be drained clean, especially in winter. If the water cannot be drained clean, it often causes premature aging of the rubber of the water pressure plate and reduces the service life of the water pressure plate;
The correct way to drain water is to do it after the vulcanization and insulation is completed and before the vulcanizer is disassembled. If the water is drained after the machine is disassembled, the water in the water pressure plate may not be completely discharged.